ALTER TABLE添加一列并且添加 检查 约束
oracle的约束
* 如果某个约束只作用于单独的字段,即可以在字段级定义约束,也可以在表级定义约束,但如果某个约束作用于多个字段,
必须在表级定义约束
* 在定义约束时可以通过constraint关键字为约束命名,如果没有指定,oracle将自动为约束建立默认的名称
定义primary key约束(单个字段)
create table employees (empno number(5) primary key,...)
sql>
sql> create table emp (empno number(4) not null,
2 ename varchar2(10),
3 job varchar2(9),
4 mgr number(4),
5 hiredate date,
6 sal number(7, 2),
7 comm number(7, 2),
8 deptno number(2));table created.
sql>
sql> insert into emp values (7369, 'smith', 'clerk', 7902, to_date('17-dec-1980', 'dd-mon-yyyy'), 800, null, 20);1 row created.
sql> insert into emp values (7499, 'allen', 'salesman', 7698, to_date('20-feb-1981', 'dd-mon-yyyy'), 1600, 300, 30);
1 row created.
sql> insert into emp values (7521, 'ward', 'salesman', 7698, to_date('22-feb-1981', 'dd-mon-yyyy'), 1250, 500, 30);
1 row created.
sql> insert into emp values (7566, 'jones', 'manager', 7839, to_date('2-apr-1981', 'dd-mon-yyyy'), 2975, null, 20);
1 row created.
sql> insert into emp values (7654, 'martin', 'salesman', 7698,to_date('28-sep-1981', 'dd-mon-yyyy'), 1250, 1400, 30);
1 row created.
sql> insert into emp values (7698, 'blake', 'manager', 7839,to_date('1-may-1981', 'dd-mon-yyyy'), 2850, null, 30);
1 row created.
sql> insert into emp values (7782, 'clark', 'manager', 7839,to_date('9-jun-1981', 'dd-mon-yyyy'), 2450, null, 10);
1 row created.
sql> insert into emp values (7788, 'scott', 'analyst', 7566,to_date('09-dec-1982', 'dd-mon-yyyy'), 3000, null, 20);
1 row created.
sql> insert into emp values (7839, 'king', 'president', null,to_date('17-nov-1981', 'dd-mon-yyyy'), 5000, null, 10);
1 row created.
sql> insert into emp values (7844, 'turner', 'salesman', 7698,to_date('8-sep-1981', 'dd-mon-yyyy'), 1500, 0, 30);
1 row created.
sql> insert into emp values (7876, 'adams', 'clerk', 7788,to_date('12-jan-1983', 'dd-mon-yyyy'), 1100, null, 20);
1 row created.
sql> insert into emp values (7900, 'james', 'clerk', 7698,to_date('3-dec-1981', 'dd-mon-yyyy'), 950, null, 30);
1 row created.
sql> insert into emp values (7902, 'ford', 'analyst', 7566,to_date('3-dec-1981', 'dd-mon-yyyy'), 3000, null, 20);
1 row created.
sql> insert into emp values (7934, 'miller', 'clerk', 7782,to_date('23-jan-1982', 'dd-mon-yyyy'), 1300, null, 10);
1 row created.
sql>
sql> * from emp;empno ename job mgr hiredate sal comm deptno
---------- ---------- --------- ---------- --------- ---------- ---------- ----------
7369 smith clerk 7902 17-dec-80 800 20
7499 allen salesman 7698 20-feb-81 1600 300 30
7521 ward salesman 7698 22-feb-81 1250 500 30
7566 jones manager 7839 02-apr-81 2975 20
7654 martin salesman 7698 28-sep-81 1250 1400 30
7698 blake manager 7839 01-may-81 2850 30
7782 clark manager 7839 09-jun-81 2450 10
7788 scott analyst 7566 09-dec-82 3000 20
7839 king president 17-nov-81 5000 10
7844 turner salesman 7698 08-sep-81 1500 0 30
7876 adams clerk 7788 12-jan-83 1100 20empno ename job mgr hiredate sal comm deptno
---------- ---------- --------- ---------- --------- ---------- ---------- ----------
7900 james clerk 7698 03-dec-81 950 30
7902 ford analyst 7566 03-dec-81 3000 20
7934 miller clerk 7782 23-jan-82 1300 1014 rows selected.
sql>
sql> alter table emp
2 add (
3 gender varchar(10));table altered.
sql>
sql> alter table emp
2 add constraint ck_gender
3 check (gender in ('male', 'female'));table altered.
sql>
sql> update emp set gender = 'male' where mod(empno,2) = 0;10 rows updated.
sql>
sql> select * from emp;empno ename job mgr hiredate sal comm deptno gender
---------- ---------- --------- ---------- --------- ---------- ---------- ---------- ----------
7369 smith clerk 7902 17-dec-80 800 20
7499 allen salesman 7698 20-feb-81 1600 300 30
7521 ward salesman 7698 22-feb-81 1250 500 30
7566 jones manager 7839 02-apr-81 2975 20 male
7654 martin salesman 7698 28-sep-81 1250 1400 30 male
7698 blake manager 7839 01-may-81 2850 30 male
7782 clark manager 7839 09-jun-81 2450 10 male
7788 scott analyst 7566 09-dec-82 3000 20 male
7839 king president 17-nov-81 5000 10
7844 turner salesman 7698 08-sep-81 1500 0 30 male
7876 adams clerk 7788 12-jan-83 1100 20 maleempno ename job mgr hiredate sal comm deptno gender
---------- ---------- --------- ---------- --------- ---------- ---------- ---------- ----------
7900 james clerk 7698 03-dec-81 950 30 male
7902 ford analyst 7566 03-dec-81 3000 20 male
7934 miller clerk 7782 23-jan-82 1300 10 male14 rows selected.
sql>
sql> update emp set gender = 'female' where mod(empno,2) = 1;4 rows updated.
sql>
sql> select ename, job, gender from emp order by gender, ename;ename job gender
---------- --------- ----------
allen salesman female
king president female
smith clerk female
ward salesman female
adams clerk male
blake manager male
clark manager male
ford analyst male
james clerk male
jones manager male
martin salesman maleename job gender
---------- --------- ----------
miller clerk male
scott analyst male
turner salesman male14 rows selected.
sql>
sql> insert into emp (empno, ename, gender) values (8001, 'pat', 'unknown');
insert into emp (empno, ename, gender) values (8001, 'pat', 'unknown')
*
error at line 1:
ora-02290: check constraint (sys.ck_gender) violated
sql>
sql> drop table emp;table dropped.

Hot AI Tools

Undresser.AI Undress
AI-powered app for creating realistic nude photos

AI Clothes Remover
Online AI tool for removing clothes from photos.

Undress AI Tool
Undress images for free

Clothoff.io
AI clothes remover

Video Face Swap
Swap faces in any video effortlessly with our completely free AI face swap tool!

Hot Article

Hot Tools

Notepad++7.3.1
Easy-to-use and free code editor

SublimeText3 Chinese version
Chinese version, very easy to use

Zend Studio 13.0.1
Powerful PHP integrated development environment

Dreamweaver CS6
Visual web development tools

SublimeText3 Mac version
God-level code editing software (SublimeText3)

Hot Topics











The message "Your organization has asked you to change your PIN" will appear on the login screen. This happens when the PIN expiration limit is reached on a computer using organization-based account settings, where they have control over personal devices. However, if you set up Windows using a personal account, the error message should ideally not appear. Although this is not always the case. Most users who encounter errors report using their personal accounts. Why does my organization ask me to change my PIN on Windows 11? It's possible that your account is associated with an organization, and your primary approach should be to verify this. Contacting your domain administrator can help! Additionally, misconfigured local policy settings or incorrect registry keys can cause errors. Right now

Windows 11 brings fresh and elegant design to the forefront; the modern interface allows you to personalize and change the finest details, such as window borders. In this guide, we'll discuss step-by-step instructions to help you create an environment that reflects your style in the Windows operating system. How to change window border settings? Press + to open the Settings app. WindowsI go to Personalization and click Color Settings. Color Change Window Borders Settings Window 11" Width="643" Height="500" > Find the Show accent color on title bar and window borders option, and toggle the switch next to it. To display accent colors on the Start menu and taskbar To display the theme color on the Start menu and taskbar, turn on Show theme on the Start menu and taskbar

Screen brightness is an integral part of using modern computing devices, especially when you look at the screen for long periods of time. It helps you reduce eye strain, improve legibility, and view content easily and efficiently. However, depending on your settings, it can sometimes be difficult to manage brightness, especially on Windows 11 with the new UI changes. If you're having trouble adjusting brightness, here are all the ways to manage brightness on Windows 11. How to Change Brightness on Windows 11 [10 Ways Explained] Single monitor users can use the following methods to adjust brightness on Windows 11. This includes desktop systems using a single monitor as well as laptops. let's start. Method 1: Use the Action Center The Action Center is accessible

HQL and SQL are compared in the Hibernate framework: HQL (1. Object-oriented syntax, 2. Database-independent queries, 3. Type safety), while SQL directly operates the database (1. Database-independent standards, 2. Complex executable queries and data manipulation).

"Usage of Division Operation in OracleSQL" In OracleSQL, division operation is one of the common mathematical operations. During data query and processing, division operations can help us calculate the ratio between fields or derive the logical relationship between specific values. This article will introduce the usage of division operation in OracleSQL and provide specific code examples. 1. Two ways of division operations in OracleSQL In OracleSQL, division operations can be performed in two different ways.

Oracle and DB2 are two commonly used relational database management systems, each of which has its own unique SQL syntax and characteristics. This article will compare and differ between the SQL syntax of Oracle and DB2, and provide specific code examples. Database connection In Oracle, use the following statement to connect to the database: CONNECTusername/password@database. In DB2, the statement to connect to the database is as follows: CONNECTTOdataba

The famous activation script MAS2.2 version supports digital activation again. The method originated from @asdcorp and the team. The MAS author calls it HWID2. Download gatherosstate.exe (not original, modified) from https://github.com/massgravel/Microsoft-Activation-Scripts, run it with parameters, and generate GenuineTicket.xml. First take a look at the original method: gatherosstate.exePfn=xxxxxxx;DownlevelGenuineState=1 and then compare with the latest method: gatheros

In iOS 17, Apple introduced several new privacy and security features to its mobile operating system, one of which is the ability to require two-step authentication for private browsing tabs in Safari. Here's how it works and how to turn it off. On an iPhone or iPad running iOS 17 or iPadOS 17, Apple's browser now requires Face ID/Touch ID authentication or a passcode if you have any Private Browsing tab open in Safari and then exit the session or app to access them again. In other words, if someone gets their hands on your iPhone or iPad while it's unlocked, they still won't be able to view your privacy without knowing your passcode
